Back

DECG-03A - $1,500 + GST

Mindray

  • Small Animal
  • Bovine
  • Equine
  • Ovine
  • Exotics

The DECG-03A Automatic electrocardiograph (ECG) is a complete transthoracic measurement, interpretation and analysis machine, with digital filtering to avoid baseline drifting and interference from AC, and baseline Auto-adjustments to optimise printing position.

 

Price - $1,500.00  + GST
Product is 'New Old Stock'. Please contact us directly to enquire further or to purchase.

What's next? Contact us for prices & ordering.
Email us about this product Or call us: 1300 798 747

Price - $1,500.00  + GST
Product is 'New Old Stock'. Please contact us directly to enquire further or to purchase.

Features

  • Automatic ECG measurement and analysis
  • Complete digital filter to avoid baseline drifting and interference from AC, EMG
  • Auto-adjusts baseline to optimize printing position
  • Full digital processing
  • Simultaneous 12-lead acquisition
  • Thermal recorder with high resolution printing
  • Up to 4-hour battery working time
  • Auto/manual operation mode
  • Lead-off detection and display
  • Selectable printing formats: Standard 3 leads, rhythm lead, 3/2 leads, manual 1 lead
  • 140 patient data storage
  • LCD Display (Narrow/Wide) selectable
Weight

Approx 2.5kg

Dimensions

30cm W x 26cm H x 7.5cm D

Operation Environment

Temperature Transport: -20~50°C / Storage: -10~40°C / Working: 5~40°C
Relative Humidity Transport: -25-95% / Storage: 25-95% / Working: 25-85% (no condensation on either)
Atmospheric Pressure Transport: 70kPa~106kPa / Storage: 70kPa~106kPa  / Working: 86kPa~106kPa

Performance Specifications

Display: 320 x 240 dot LCD (Wide Screen) / 192 x 64 dot (Narrow Screen)

Mains Supply Rated input voltage (100V~115V/220V~240V) | Rated frequency (50/60Hz) | Rated input power (35A)

Built-in Lithium Battery Pack Rated voltage (14.4V)

Rated capacity (1600mAh) 
Charge mode (Constant current/voltage)
Charge current - standard (0.2C5A,320mA)
Charge voltage - standard (17±0.1V)
Continuous charge current (1600mA max)
Continuous discharge current (1600mA max)
Cycle life ≥300 times
Power Consumption 35VA (max)
Recorder 3-channel thermal dot-matrix printer
Printing format 2X6+1R/4X3
Record Paper Folded thermosensitive paper, 80mm width / Rolled thermosensitive paper, 80mm width
Effective width 72mm
Paper Speed 5mm/s, 10mm/s, 25mm/s, 50mm/s
Accuracy of data: ±5% (x-axis), ±5% (y-axis)
HR Recognition Technique: Peak-peak detection
HR Range: 30bpm~300bpm
Accuracy: ±1bpm

ECG Unit

Leads: 12 standard leads
Acquisition Mode: simultaneously 12 leads
A/D Resolution: 12bits
Time Constant: ≥3.2s
Frequency Response: 0.05Hz~150Hz
Sensitivity 2.5, 5, 10, 20: (mm/mv)
Input Impedance: 50MΩ (10Hz)
Input Circuit Current: ≤50nA
Input Voltage Range: <±5mVpp
Calibration Voltage: 1mV±3%
Noise: <15µ Vp-p
Multichannel crosstal: ≤0.5mm
Filter AC Filter: On/Off
DFT Filter: 0.05/0.15/0.25/0.5/ADP
EMG Filter: 25Hz/35Hz/OFF
LOWPASS Filter: 150Hz/100Hz/75Hz
CMRR >100B

Patient Leakage Current

<10µ A (220v~240V)

Patient Auxiliary Current

<0.1µ A (DC)

External Input/Output (Opt)

Input ≥100kµ ; Sensitivity 10mm/V±5%,Single ended
Input ≥100kµ ; Sensitivity 1V/mV±5%,Single ended

Manufacturer

Mindray

Get Social with BCF

Stay in Contact with BCF

Subscribe to receive email updates from us on training events, articles of interest, special offers and more…